Major Orthopaedic Instruments Set
Makintosh Metre
A Rubber Sheet, also called a Mackintosh Sheet or Mattress Protector, is a waterproof protective sheet used in hospitals, clinics, maternity wards, and homes to protect bedding or mattresses from fluids such as urine, blood, or other body discharges. It is especially common in patient care, delivery rooms, and infant care.
Malaria Rapid Diagnostic Test Kit (MRDT)
The MRDT is a quick, simple test used to detect the presence of malaria parasites (specifically their antigens) in a person’s blood. It provides results within 15–20 minutes and is especially useful in field settings and healthcare facilities where microscopy is not available.
Manual Craniotomy Drill
A Manual Craniotomy Drill is a hand-operated surgical instrument used to create openings in the skull (burr holes) during a craniotomy procedure. It allows surgeons to penetrate the cranial bone safely and precisely without causing damage to the underlying brain tissue.
MANUAL LENSMETER GJD-1
Optical Equipments manual lensmeter 1. Outer reading 2. 25D measurement
3. Wide field of vision observation 4. AC/DC The Lensmeter is used to
measure the diopters of spherical lens and cylinder lens, the axis of cylinder
lens, the strength and the baseline direction of shuttle lens, it can also stamp
the optical center of lens, the axis of cylinder len and the base direction of
shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When
Dc) has clear readings and graduations as well as high objective precision and
reliabilities except that it can be operated easily and conveniently, AU the
lenses and the made glasses can be measured by it, therefore, it is a required
and ideal measuring instrument for glasses manufactures, glasses stores and
ophthalmological hospitals.
Manual Vacuum Aspiration (MVA) Kit – Double Valve
The MVA Kit (Double Valve) is a manual suction device designed for uterine evacuation and management of incomplete abortion, missed miscarriage, or endometrial biopsy. It provides a safe, effective, and minimally invasive method for performing uterine aspiration using manual vacuum pressure. The double-valve system allows continuous suction without loss of vacuum, improving efficiency and control during procedures.
Manual Vacuum Aspiration (MVA) Set
The MVA set consists of a handheld aspirator (syringe) and a range of sterile, flexible cannulae of various sizes. The system creates negative pressure manually, eliminating the need for electrical suction devices. It is widely used in outpatient and low-resource settings due to its portability, simplicity, and effectiveness.
Matrix Band Holder (Tofflemire Retainer)
A Matrix Band Holder, also known as a Tofflemire Retainer, is a dental instrument used to secure a matrix band around a tooth during the placement of restorative materials such as amalgam or composite. It helps recreate the natural contour and contact of the tooth while preventing overhangs and ensuring proper adaptation of the filling.
Components:
-
Head: Holds the matrix band securely; may be straight or contra-angled.
-
Locking Vise: Tightens and locks the matrix band in place.
-
Long Knob (Adjusting Screw): Expands or contracts the loop size of the band to fit around the tooth.
-
Short Knob (Locking Nut): Locks the band firmly to prevent slipping during restoration.
Mattress with Mackintosh
The mattress is made of high- or medium-density foam to provide comfort and firm body support. It is encased in a Mackintosh material—a waterproof, easy-to-clean, and durable cover often made from medical-grade PVC or rubberized fabric.
Mayo Trolley
The Mayo Trolley consists of a stainless steel rectangular tray mounted on an adjustable-height frame with four castor wheels for mobility. The tray can be positioned over or beside the operating table, depending on the surgeon’s needs. Its simple yet durable construction ensures sterility, stability, and easy cleaning, making it essential in all surgical and clinical setups.
Mercurial Blood Pressure Machine
This is a device used to measure blood pressure, composed of an inflatable cuff to collapse and then release the artery under the cuff in a controlled manner, and a mercury or aneroid manometer to measure the pressure. It is always used with a means to determine at what pressure blood flow is just starting, and at what pressure it is unimpeded
Also known as a Desk Type Mercury Sphygmomanometer composed of an inflatable cuff to collapse and then release the artery under the cuff in a controlled manner and a mercury manometer to measure the pressure.
It is always used with a means to determine at what pressure blood flow is just starting, and at what pressure it is unimpeded
Also known as a Desk Type Mercury Sphygmomanometer
Mindray Auto Hematology Analyzer (BC-10)
Key Features
1. Analytical Parameters
The BC-10 provides 20+ standard parameters and 3 histograms (WBC, RBC, PLT), including:
-
WBC (White Blood Cell count)
-
LYM#, MON#, GRA# – 3-part differential of WBC
-
RBC (Red Blood Cell count)
-
HGB (Hemoglobin)
-
HCT (Hematocrit)
-
MCV, MCH, MCHC – Red cell indices
-
PLT (Platelet count)
-
RDW-CV, RDW-SD – Red cell distribution width
-
MPV, PDW, PCT – Platelet indices
2. Measurement System
-
Principle: Electrical impedance for cell counting and non-cyanide colorimetry for hemoglobin measurement.
-
Throughput: Up to 30–60 samples per hour, depending on mode.
-
Sample Volume: Only 10–20 µL of whole blood needed.
-
Accuracy: High precision with CV <2% for RBC and HGB.
3. Operation and Interface
-
Display: 8-inch color LCD touchscreen for easy navigation.
-
User Interface: Intuitive software with customizable test settings.
-
Data Management: Stores up to 20,000–50,000 patient results.
-
Printer: Built-in thermal printer for instant report generation.
-
Connectivity: USB ports and optional LIS (Laboratory Information System) integration.
4. Reagent System
-
Works with 3 reagents (diluent, lyse, and cleaner).
-
Low reagent consumption, ensuring cost-effective operation.
-
Automatic cleaning and flushing minimize clogging and maintenance time.
5. Physical Design
-
Compact and lightweight: Ideal for small lab spaces.
-
Dimensions: Approx. 390 × 320 × 400 mm.
-
Weight: About 20 kg.
-
Power: AC 110–240V, 50/60Hz.
-
Environment: Operates efficiently at 15–30°C and ≤85% humidity.
6. Performance and Reliability
-
Fast turnaround time for patient samples.
-
Stable calibration and consistent performance.
-
Designed with anti-clogging technology and self-check systems.
-
Supports both venous and capillary samples.