Filter by price
Stock status
Showing 49–60 of 185 results
Finecare B-HCG Rapid Quantitative Test Kit
Key Features and Specifications
-
Test Principle: Fluorescence immunoassay.
-
Sample Type: Serum, plasma, or whole blood.
-
Measuring Range: Typically 5 – 10,000 mIU/mL (depending on analyzer version).
-
Reaction Time: Approximately 15 minutes.
-
Sample Volume: About 75 µL.
-
Storage Temperature: 4°C – 30°C.
-
Shelf Life: Valid up to the expiration date indicated on the packaging.
-
Compatible Device: Finecare FIA Analyzer (models such as Finecare Plus or Finecare FS-113).
Finecare CEA Rapid Quantitative Test:
Key Features & Specifications
-
Test principle: Fluorescence Immunoassay (FIA) for the quantitative detection of Carcinoembryonic Antigen (CEA) in human serum, plasma, or whole blood.
-
Analyte: Carcinoembryonic Antigen (CEA).
-
Measurement range: Typically 0.5 ng/mL – 200 ng/mL (may vary slightly by batch).
-
Sample types: Whole blood, serum, or plasma.
-
Turnaround time: Results available in 15 minutes.
-
Storage conditions: Test cartridges stable at 4 °C – 30 °C for up to 24 months.
-
Instrument compatibility: Requires the Finecareâ„¢ Fluorescence Immunoassay Analyzer or Finecare Plus Reader for quantitative read-out.
-
Sample volume: Approximately 75–100 µL per test.
Finecare CK-MB Rapid Quantitative Test
✅ Key Features & Specifications
-
Test principle: Fluorescence Immunoassay (FIA) for the quantitative measurement of Creatine Kinase-MB (CK-MB) in human serum, plasma, or whole blood.
-
Analyte: Creatine Kinase-MB (CK-MB).
-
Measurement range: Typically 0.5–200 ng/mL (may vary slightly depending on the lot).
-
Sample types: Whole blood, serum, or plasma.
-
Sample volume: Approximately 75–100 µL per test.
-
Turnaround time: Results available in 15 minutes.
-
Storage conditions: Test cartridges stable at 4 °C – 30 °C, with a shelf life up to 24 months.
-
Instrument compatibility: Requires a Finecareâ„¢ Fluorescence Immunoassay Analyzer (Finecare, Finecare Plus, or Finecare II) for quantitative reading.
Finecare Cortisol Rapid Quantitative Test Kit
Key Features and Specifications
-
Test Principle: Fluorescence immunoassay.
-
Sample Type: Serum, plasma, or whole blood.
-
Measuring Range: Typically 1 – 60 µg/dL (may vary with analyzer model).
-
Reaction Time: Approximately 15 minutes.
-
Sample Volume: About 75 µL.
-
Storage Temperature: 4°C – 30°C.
-
Shelf Life: Valid until the expiration date on the packaging.
-
Compatible Device: Finecare FIA Analyzer (e.g., Finecare FS-113, Finecare Plus).
Finecare CRP Control Kit
Finecare CRP Rapid Quantitative Test
✅ Key Features & Specifications
-
Test principle: Fluorescence Immunoassay (FIA) for the quantitative determination of C-Reactive Protein (CRP) concentration in human serum, plasma, or whole blood.
-
Analyte: C-Reactive Protein (CRP).
-
Measurement range: Typically 0.5 mg/L – 200 mg/L (may vary slightly depending on lot or analyzer version).
-
Sample types: Whole blood, serum, or plasma.
-
Turnaround time: Approximately 3–15 minutes per test.
-
Storage conditions: Test cartridges stable at 4 °C – 30 °C with a shelf life of up to 24 months.
-
Instrument compatibility: Requires a Finecareâ„¢ Fluorescence Immunoassay Analyzer (such as Finecare, Finecare Plus, or Finecare II) for quantitative measurement.
-
Sample volume: Around 75–100 µL per test.
Finecare cTnI (Cardiac Troponin I) Control Kit
Key Features and Specifications
-
Test Principle: Quality control for fluorescence immunoassay.
-
Sample Type: Control serum or plasma.
-
Levels: Typically includes low and high cTnI concentration controls.
-
Storage Temperature: 2°C – 8°C (refrigeration required).
-
Stability: Follow manufacturer instructions for expiration and usage.
-
Intended Device: Finecare FIA Analyzer (e.g., Finecare FS-113, Finecare Plus).
Finecare cTnI / CK-MB / Myoglobin (Myo) Rapid Quantitative Test
✅ Key Features & Specifications
-
Test principle: Fluorescence Immunoassay (FIA) for the simultaneous quantitative detection of cardiac markers:
-
Cardiac Troponin I (cTnI)
-
Creatine Kinase-MB (CK-MB)
-
Myoglobin (Myo)
-
-
Analytes: cTnI, CK-MB, and Myoglobin in human serum, plasma, or whole blood.
-
Sample types: Whole blood, serum, or plasma.
-
Sample volume:
-
cTnI: ~75 µL (serum/plasma), ~100 µL (whole blood)
-
CK-MB: ~75–100 µL
-
Myo: ~75–100 µL
-
-
Turnaround time: Results available in approximately 15 minutes.
-
Measuring/detection ranges:
-
cTnI: 0.1–50 ng/mL
-
CK-MB: 0.5–200 ng/mL
-
Myoglobin: 5–500 ng/mL
-
-
Storage conditions: Cartridges stable at 4–30 °C, shelf life up to 24 months.
-
Instrument compatibility: Requires a Finecareâ„¢ Fluorescence Immunoassay Analyzer (Finecare, Finecare Plus, or Finecare II) for quantitative reading.
Finecare cTnI Rapid Quantitative Test
✅ Key Features & Specifications
-
Test principle: Fluorescence Immunoassay (FIA) for the quantitative detection of cardiac troponin I (cTnI) in human whole blood, serum, or plasma.
-
Intended use: An aid in the diagnosis of acute myocardial infarction (AMI) and in monitoring patients with suspected cardiac injury or at risk of major adverse cardiac events (MACE).
-
Sample types: Whole blood, serum, or plasma.
-
Sample volume: Approximately 75 µL (serum/plasma) or 100 µL (whole blood) per test.
-
Turnaround time: Results available in about 15 minutes.
-
Measurement range: Typically 0.1 ng/mL to 50 ng/mL.
-
Storage conditions: Cartridges stable at 4 °C – 30 °C, with a shelf life of up to 24 months.
-
Instrument compatibility: Requires a Finecareâ„¢ Fluorescence Immunoassay Analyzer (e.g., Finecare, Finecare Plus, or Finecare II) for quantitative result reading.
Finecare D-Dimer Rapid Quantitative Test
✅ Key Features & Specifications
-
Test principle: Fluorescence immunoassay for quantitative measurement of D-Dimer in human whole blood or plasma.
-
Measuring range: 0.1 mg/L – 10 mg/L (detection limit approximately 0.1 mg/L).
-
Sample types: Whole blood or plasma (serum not recommended).
-
Turnaround time: Approximately 15 minutes per test.
-
Storage conditions: Test cartridges stable at 4 °C – 30 °C with a shelf life of up to 24 months.
-
Instrument compatibility: Requires the Finecareâ„¢ Fluorescence Immunoassay (FIA) Analyzer for quantitative read-out.
Finecare Estradiol (E2) Rapid Quantitative Test
✅ Key Features & Specifications
-
Test principle: Fluorescence Immunoassay (FIA) for the quantitative measurement of Estradiol (E2) in human serum, plasma, or whole blood.
-
Analyte: Estradiol (E2).
-
Measurement range: Typically 20–2000 pg/mL (may vary slightly depending on the lot).
-
Sample types: Whole blood, serum, or plasma.
-
Sample volume: Approximately 75–100 µL per test.
-
Turnaround time: Results available in 15 minutes.
-
Storage conditions: Test cartridges stable at 4 °C – 30 °C, with a shelf life up to 24 months.
-
Instrument compatibility: Requires a Finecareâ„¢ Fluorescence Immunoassay Analyzer (Finecare, Finecare Plus, or Finecare II) for quantitative reading.
Finecare Ferritin Rapid Quantitative Test Kit
Summer health medical supplies limited.
We are happy to serve you fro all your health, medical and hospital supplies. Contact Us Here for any enquiries that you may need clarification.