Filter by price
Stock status
Showing 313–324 of 582 results
iChem 535- Semi Auto Chemistry Analyzer- Immunoassy
Key visible features include:
-
A large color touchscreen for intuitive operation and data display.
-
A sample holder and pipette area on the left, where reagents or samples are loaded.
-
The label "Semi-Auto Chemistry analyzer", indicating it requires some manual steps (like sample loading) but performs the measurements automatically.
-
The inset diagram on the top right shows a sample rotor layout, likely representing how samples are organized for testing.
Ichroma Alpha-Fetoprotein (AFP)
Key Features
1. Quantitative AFP Measurement
-
Measures Alpha-Fetoprotein levels accurately to assist in:
-
Diagnosis and monitoring of primary liver cancer
-
Evaluation of liver cirrhosis and chronic hepatitis
-
Prenatal screening, including neural tube defect risk assessment
-
2. Fast Turnaround Time
-
Typically 10–12 minutes from sample loading to result.
3. Fluorescence Immunoassay (FIA) Technology
-
Uses fluorescent-labeled antibodies for high sensitivity and specificity.
-
Provides reliable quantification comparable to standard laboratory analyzers.
4. Easy Operation
-
Simple test cartridge format.
-
Automated reading on ichroma analyzers.
-
Minimal user training required.
5. Small Sample Volume
-
Requires only a small blood sample (whole blood, serum, or plasma).
6. Portable & Convenient
-
Works with compact ichroma analyzers.
-
Suitable for point-of-care and laboratory environments.
Clinical Applications
-
Screening for Hepatocellular Carcinoma (HCC)
-
Monitoring treatment response in liver cancer patients
-
Assessment of liver diseases such as cirrhosis or chronic hepatitis
-
Prenatal screening (maternal serum AFP)
-
Follow-up testing for high-risk patients
ichroma Anti-CCP – Anti–Cyclic Citrullinated Peptide Antibody Test
Key Features
-
Quantitative Anti-CCP measurement: Helps identify autoimmune activity linked to rheumatoid arthritis.
-
High specificity: Anti-CCP antibodies are considered one of the most specific markers for RA.
-
Fast results: Delivers results within minutes on ichroma analyzers.
-
Easy workflow: Single-use cartridge requiring minimal sample preparation.
-
Reliable performance: Uses fluorescently labeled anti-CCP detection antibodies for accurate measurement.
Clinical Applications
-
Early diagnosis of Rheumatoid Arthritis
-
Differentiating RA from other inflammatory or autoimmune conditions
-
Assessing disease severity and prognosis
-
Supporting treatment planning and monitoring response to therapy
Principle of the Test
The ichroma Anti-CCP assay is based on fluorescence immunoassay technology:
-
The patient sample is added to the test cartridge.
-
Anti-CCP antibodies (if present) bind to CCP antigens coated with fluorescent markers.
-
The ichroma analyzer measures fluorescence intensity, which is proportional to Anti-CCP concentration.
Typical Output
-
Quantitative Anti-CCP level displayed on the analyzer
-
Supports clinical evaluation alongside RF (Rheumatoid Factor) and ESR/CRP results
ichroma CEA – Carcinoembryonic Antigen Test Cartridge
Key Features
-
Quantitative CEA measurement: Provides precise detection of CEA levels for oncology monitoring.
-
Fast results: Delivers results within minutes with ichroma analyzers.
-
User-friendly format: Disposable cartridges with simple sample application.
-
High analytical performance: Reliable fluorescence-based signal detection.
-
Small sample volume: Requires minimal serum or plasma.
Clinical Applications
-
Monitoring colorectal cancer progression or recurrence
-
Evaluation of other CEA-producing cancers, such as gastric, pancreatic, lung, and breast cancers
-
Assessing treatment response during chemotherapy or surgical follow-up
-
Supporting diagnosis when used alongside imaging and clinical findings
Principle of the Test
The ichroma CEA assay operates on a fluorescence immunoassay principle:
-
The sample is added to the test cartridge.
-
CEA in the sample binds to fluorescently labeled anti-CEA antibodies.
-
The ichroma analyzer measures fluorescence intensity, which correlates with CEA concentration.
ichroma CRP – C-Reactive Protein
Key Features
-
Quantitative CRP measurement: Provides precise detection of C-Reactive Protein, an acute-phase inflammatory marker.
-
Rapid results: Produces clinically useful results within minutes on ichroma analyzers.
-
User-friendly design: Single-use cartridges ensure easy operation and minimal preparation.
-
Flexible sample types: Supports whole blood (capillary/venous), serum, or plasma.
-
High analytical performance: Uses fluorescent antibody labeling for accurate, reproducible measurements.
Clinical Applications
-
Diagnosis and monitoring of bacterial infections
-
Differentiating bacterial vs. viral causes of illness
-
Assessing systemic inflammation
-
Monitoring treatment response in infectious or inflammatory conditions
-
Supporting decisions in antibiotic therapy
Principle of the Test
The assay uses a fluorescence immunoassay method:
-
The sample is applied to the cartridge.
-
CRP in the sample binds to fluorescently tagged anti-CRP antibodies.
-
The ichroma analyzer measures fluorescence intensity, which corresponds to CRP concentration.
ichroma D-Dimer
Key Features
1. Quantitative D-Dimer Measurement
-
Provides precise numerical values for D-Dimer concentration.
-
Essential for:
-
Ruling out Deep Vein Thrombosis (DVT)
-
Ruling out Pulmonary Embolism (PE)
-
Detection of Disseminated Intravascular Coagulation (DIC)
-
2. Rapid Turnaround Time
-
Results available in 10–12 minutes.
-
Ideal for emergency rooms, clinics, and point-of-care settings.
3. High Sensitivity & Specificity
-
Fluorescent immunoassay technology enhances accuracy.
-
Reliable for triaging patients with suspected clotting disorders.
4. Easy-to-Use Cartridge System
-
Simple sample application.
-
Automated analysis once inserted into the ichroma reader.
-
Minimal training required.
5. Small Sample Volume
-
Works with capillary blood, venous blood, plasma, or serum.
-
Convenient for rapid emergency testing.
6. Portable Testing System
-
Works with compact ichroma analyzers.
-
Allows decentralized, bedside, or near-patient testing.
Clinical Applications
-
Exclusion of venous thromboembolism (VTE)
– Deep Vein Thrombosis (DVT)
– Pulmonary Embolism (PE) -
Monitoring and evaluation of DIC
-
Assessment of coagulation activity in critically ill patients
-
Post-operative or trauma patient monitoring
-
Emergency department triage of patients with chest pain or shortness of breath
ichroma HbA1c
Key Features
1. Accurate HbA1c Quantification
-
Measures glycated hemoglobin (HbA1c) as a percentage (%).
-
Supports:
-
Diagnosis of diabetes
-
Monitoring glycemic control
-
Therapy adjustment
-
2. Rapid Test Time
-
Results available in ~5 minutes, depending on the analyzer model.
-
Suitable for clinics, outpatient departments, and point-of-care testing.
3. High Precision FIA Technology
-
Uses fluorescent-labeled antibodies for high sensitivity.
-
Delivers results comparable with laboratory-grade HbA1c analyzers.
4. Simple & User-Friendly Cartridge System
-
Requires a small whole blood sample.
-
Easy specimen application and loading.
-
Minimal technician training needed.
5. Compact & Portable System
-
Works with small ichroma analyzers.
-
Ideal for decentralized testing such as diabetes centers and community health facilities.
Clinical Applications
-
Diagnosis of diabetes mellitus
-
Monitoring long-term glycemic control
-
Assessing risk for diabetic complications
-
Evaluation of treatment effectiveness
-
Screening in community and outpatient settings
ichroma Luteinizing Hormone (LH)
Key Features
1. Quantitative LH Measurement
-
Measures LH levels in whole blood, serum, or plasma.
-
Provides numeric results helpful in assessing ovulation timing, LH surge, infertility investigations, and pituitary function.
2. Rapid Testing
-
Turnaround time is typically 10–15 minutes, suitable for clinics, labs, and fertility centers.
3. FIA Technology (Fluorescent Immunoassay)
-
Uses fluorescent-labeled antibodies to detect LH with high sensitivity and specificity.
4. Easy Operation
-
Simple sample application onto the test cartridge.
-
Insert cartridge into the ichroma analyzer for automatic reading.
-
Minimal user training required.
5. Portable and Compact
-
The analyzer is small, lightweight, and suitable for both laboratory and bedside/clinic use.
6. Reliable & Reproducible Results
-
Designed to reduce human error.
-
Built-in calibration and quality control features depending on the ichroma model (e.g., ichroma II, ichroma S).
7. Wide Clinical Applications
-
Ovulation detection
-
Infertility assessment
-
Evaluation of menstrual irregularities
-
Hormonal monitoring in reproductive health
-
Supporting clinicians in diagnosing endocrine disorders
Ichroma Progesterone
ichroma PSA Prostate-Specific Antigen
ey Features
1. Quantitative PSA Measurement
-
Produces accurate numeric values of PSA concentration.
-
Supports:
-
Prostate cancer screening
-
Monitoring treatment response
-
Post-treatment surveillance
-
Assessment of benign prostatic hyperplasia (BPH) and prostatitis
-
2. Rapid Turnaround Time
-
Results typically available in 10–12 minutes.
-
Ideal for outpatient clinics, urology units, and point-of-care settings.
3. High Sensitivity & Specificity
-
Fluorescence immunoassay technology ensures precise and reproducible results.
-
Good clinical performance comparable to laboratory analyzers.
4. Easy-to-Use Cartridge Format
-
Simple preparation: apply sample → insert into analyzer → get results.
-
Minimal training required.
5. Small Sample Volume
-
Works with whole blood, plasma, or serum.
-
Suitable for fast and convenient testing.
6. Portable & Compact System
-
Compatible with compact ichroma analyzers.
-
Useful in clinics, mobile screening programs, and decentralized testing points.
ichroma T3 – Total Triiodothyronine (T3)
Key Features
-
Quantitative T3 measurement: Detects total circulating Triiodothyronine levels for accurate thyroid assessment.
-
Fast turnaround time: Provides results within minutes using automated fluorescence detection.
-
Easy to use: Utilizes a disposable cartridge format compatible with ichroma instruments.
-
Small sample requirement: Typically requires only a small volume of serum or plasma.
-
High sensitivity and specificity: Uses T3-specific antibodies to ensure reliable results.
Clinical Applications
-
Assessment of thyroid disorders, including hyperthyroidism and hypothyroidism
-
Monitoring of thyroid hormone replacement therapy
-
Evaluation of metabolic function related to thyroid hormones
-
Investigation of symptoms such as fatigue, weight changes, and abnormal thyroid-stimulating hormone (TSH) levels
Principle of the Test
The assay uses a fluorescence immunoassay principle:
-
Patient sample is applied to the cartridge.
-
T3 molecules in the sample bind to fluorescently labeled antibodies.
-
The ichroma analyzer measures emitted fluorescence to determine T3 concentration.
ichroma T4 (Total Thyroxine)
Key Features
1. Quantitative Total T4 Measurement
-
Provides precise numerical values for total T4 concentration.
-
Helps in evaluating:
-
Hypothyroidism
-
Hyperthyroidism
-
Thyroid hormone treatment response
-
Thyroid hormone-binding abnormalities
-
2. Fast Turnaround Time
-
Results available in 10–12 minutes.
-
Ideal for endocrine clinics, general hospitals, and point-of-care testing.
3. Fluorescence Immunoassay Technology
-
Uses fluorescent-labeled antibodies.
-
Ensures high accuracy and strong analytical performance comparable to standard laboratory systems.
4. Easy-to-Use Cartridge Format
-
Simple sample application.
-
Automated reading by the ichroma analyzer.
-
Minimal user training required.
5. Small Sample Requirements
-
Works with whole blood, plasma, or serum.
-
Suitable for routine thyroid evaluation.
6. Compact and Portable System
-
Compatible with lightweight ichroma analyzers.
-
Enables decentralized testing where rapid results are needed.
Clinical Applications
-
Diagnosis of hyperthyroidism and hypothyroidism
-
Monitoring thyroid hormone therapy
-
Evaluation of thyroid gland activity
-
Assessment of thyroid-binding protein disorders
-
Screening in general practice and endocrine clinics